1. K-State home
  2. »C-NAP
  3. »Research Cores
  4. »Electroencephalography Core

Cognitive and Neurobiological Approaches to Plasticity

Cognitive & Neurobiological Approaches to Plasticity

Contact information

Kansas State University
Department of Psychological Sciences
492 Bluemont Hall
1114 Mid-Campus Drive
Manhattan,KS 66506
Phone: (785) 532-6850

Cite Us!
P20GM113109

Electroencephalography Core

The Electroencephalography (EEG) Core provides CNAP researchers with access to critical tools and resources needed for cognitive neuroscience research. The Core is a dedicated multi-user research facility that was established in 2019. Located within the Department of Psychological Sciences, it is the only COBRE-funded EEG Core in the state of Kansas, providing resources, equipment, and technical support to enhance the
research capabilities of CNAP primary projects and programs. 

Facilities and Equipment

The EEG Core has three EEG systems available to users.

Bio Semi 

The BioSemi ActiveTwo system is equipped with up to 104 channels, a DC amplifier and 24-bit resolution. Our BioSemi ActiveTwo system uses electrode gel (SignaGel) and three cap sizes for reliable measurement. It also includes individual leads/connectors to capture facial and muscle activity. The ActiveTwo system is compatible with MEG/MCG and suitable for EEG, electrocardiogram (ECG) as well as electromyography (EMG) measurements. The ActiveTwo is battery powered with high-speed fiber optic data transfer, which makes the subject fully optically and galvanically isolated from any mains. The BioSemi ActiveTwo system is specifically designed to be used in research applications only. The system is freely configurable hardware and completely open-source software.

OpenBCI Mobile/Wireless EEG Systems

Our OpenBCI mobile system offers three (small, medium, and large) EEG Electrode Caps, each with their own Cyton + Daisy Biosensing Boards (16-Channels). The OpenBCI Cyton Board and OpenBCI Daisy Module (which plugs into the OpenBCI Cyton Board) can be used to sample up to 16 channels of brain activity (EEG), muscle activity (EMG), and heart activity (ECG). The system communicates wirelessly to a computer via the OpenBCI USB dongle using RFDuino radio modules. It can also communicate wirelessly to any mobile device or tablet compatible with Bluetooth Low Energy (BLE). The CytonDaisy Board samples data at 125 Hz on each of its 16 channels. The OpenBCI software can be used in conjunction with Matlab, Neuromore, OpenViBE, Lab Streaming Layer (LSL), BrainBay, and BioEra. OpenBCI data can be analyzed using EEGLAB, FieldTrip, EEG netsand ERPLAB.

MagStim/Electrical Geodesic Inc. (EGI)

This system offers six 64-channel Geodesic Sensor Nets (GSN) in three sizes with whole-head coverage evenly spaced over the entire scalp, cheeks, and back of neck. Our system includes Net Amps 300 series of amplifiers with Net Station 5 suite of software for EEG acquisition, review, and analysis. Net Station software saves data files in Metafile Format (MFF), which can be exported to the EDF+ format, MATLAB, EEGLAB, FieldTrip, or your own custom software. The GSN works for standard one-to-two-hour experiments. Application time for the sponge-based hydrocel GSN can take only fifteen minutes, with a simple saline solution.

Core Services

The EEG Core not only provides access to research facilities, and equipment, but also provides researchers with valuable resources and support for conducting their EEG-based research projects.  The Core staff are available to assist with the following activities: 

  • Providing input for study design, collection, and analyses
  • Providing data support for planned studies, including data collection, programming, and experiment session troubleshooting when problems arise
  • Assisting with customized scripts for data importing, cleaning, and analyses
  • Ensuring that requirements for an experiment are met prior to full data collection (e.g., IRB approval letter, test running programs, timing tests for stimuli, and speaking to program support to resolve any issues in EEG and/or computer equipment)

Staff

Alexandria ZakrzewskiCore Director

Dr. Alexandria Zakrzewski serves as the EEG Core Director. Dr. Zakrzewski is a Research Assistant Professor in Cognitive Psychology. Her responsibilities have include upgrading and maintaining current EEG laboratories to meet state-of-the-art standards. She also works to ensure accessibility of the core, and assists users in the conduct of research using the EEG systems. She hosts workshops and regular advisory meetings with project personnel. Dr. Zakrzewski also developed an experimental script suite and manuals for users to easily integrate their own experimental designs, methods, and stimuli using available programming software (e.g., Experiment Builder, Matlab, E-Prime). She supervises the Core graduate research assistant as well as undergraduate research assistants. She is also responsible for daily management of laboratory space and equipment use, maintaining ethical compliance, and supporting a space for CNAP researchers to meet their project goals in a timely manner.

Technical Advisor

Dr. Matthew Wisniewski is an Assistant Professor in Cognitive Psychology and an expert in EEG research using both event-related potential (ERP) methods as well as time-frequency analyses. He provides core users guidance on collection and statistical analyses of EEG data and
helps with facility development, including collaborations with the Neuroinformatics Core and planned expansions for CNAP's Phase 2 COBRE proposal.

Core Advisor

Dr. Lester Loschky is a Professor of Cognitive Psychology and the Associate Director of CNAP. He is an expert in visual cognition and specializes in studying eye movements. He has been actively involved in the development of the EEG Core since it's inception, and advises on EEG Core management and research development. 

Contact

Interested researchers can contact Dr. Zakrzewski to learn more about the EEG Core facilities and services or to schedule a tour.